site stats

Bk precision 885

WebTL885D B&K Precision Test Accessories - Other Shorting Bar for models 885 & 886 datasheet, inventory, & pricing. Skip to Main Content (800) 346-6873 Contact Mouser (USA) (800) 346-6873 Feedback Change Location English Español $ USD United States Please confirm your currency selection: Mouser Electronics - Electronic Components Distributor All WebApr 12, 2007 · B&K Precision 885 Synthesized In-Circuit LCR/ESR Meter with SMD Probe, 10kHz Max Test Frequency Brand: B&K Precision About this item High accuracy LCR/ESR meters were the first handheld meters of their type on the market, offering fast, reliable, and versatile testing at a low cost 100 Hz, 120 Hz, 1 kHz, 10 kHz test …

Bk precision model 886 manual - United States Guidelines …

WebB&K Precision : Product Category: Test Accessories - Other : RoHS: Details: Product: Accessories : Equipment Type: Test Equipment : Accessory Type: Shorting Bar : Color: … WebJun 11, 2024 · bk-precision 801 esr 100v-leakage in-out-of circuit capacitor analyst sm bk-precision 830 autoranging capacitance meter 1980 sm bk-precision 885 886 handheld lrc meter 2006 op sm bk-precision 960 pm-273c transistor radio analyst szerviz muszer sm bk-precision av-1a 25vrms rf probe sm BK Precision 830 Autoranging Capacitance … impact on education colorado https://dcmarketplace.net

BK Precision 885 and 886 User Manual - Cloudinary

WebBC885 B&K Precision Component Testers 885/886 120V AC Adapter datasheet, inventory, & pricing. Skip to Main Content (800) 346-6873 Contact Mouser (USA) (800) 346-6873 Feedback Change Location English Español $ USD United States Please confirm your currency selection: Mouser Electronics - Electronic Components Distributor All Filter your … WebThe BK Precision 885 Synthesized In-Circuit LCR/ESR Meter with IR RS-232, 10kHz offers a wide range of test frequencies up to 10kHz and many measurement parameters including Z, L, C, DCR, ESR, D, Q, and as Ø … WebB&K Precision was founded in 1951 and is headquartered in Yorba Linda, California. Since 1951 the B&K Precision name has represented quality, consistency, and value. We take pride in supplying outstanding products and excellent service at fair prices. Full certification by the International Organization for Standardization (ISO 9001:2015 ... impact on economic growth

BK Precision AK IR - Electronic Test Equipment

Category:B&K Precision Corporation

Tags:Bk precision 885

Bk precision 885

B&K Precision Corporation

Webitem 3 BK PRECISION MODEL 885 SYNTHESIZED IN-CIRCUIT LCR/ESR METER BK PRECISION MODEL 885 SYNTHESIZED IN-CIRCUIT LCR/ESR METER . $299.90. Free shipping. item 4 BK Precision 885 High Accuracy LCR ESR 10kHz Meter with Kelvin Leads *Tested* BK Precision 885 High Accuracy LCR ESR 10kHz Meter with Kelvin Leads … WebBK Precision BC 885 120V AC Wall Adapter: Not Available: Discontinued: BC 885-220V: BK Precision BC 885-220V Power Adapter for Models 885 and 886, 220V AC: Not Available: Discontinued: BE 12: BK Precision BE 12 9VDC/300mA AC Adapter, Center + MSRP $24.00. Sale $19.48: BE 9:

Bk precision 885

Did you know?

WebBK Precision 885 and 886 User Manual - Cloudinary WebBK Precision 885-220V Synthesized In-Circuit LCR/ESR Meter, 0.5% Accuracy, 10kHz, 220VAC Line Input: Not Available: Discontinued: 886-220V: BK Precision 886-220V Synthesized In-Circuit LCR/ESR Meter, 0.5% Accuracy, 100kHz, 220VAC Line Input: Not Available: Replaced By: 880BKPRECISION: Data Sheet: (512 KB)

WebThe B&K Precision models 885 and 886 synthesized in-circuit LCR/ESR meters are the first handheld meters of this type on the market, with a wide range of test frequencies up to 10 kHz for model 885 and 100 kHz for model 886, many measurement parameters including Z, L, C, DCR, ESR, D, Q, and Ø as well. The 885 and 886 are designed for both ... WebBK Precision 885 Synthesized In-Circuit LCR/ESR Meter, 0.5% Accuracy, 10kHz: Not Available: Replaced By: 880BKPRECISION: 885-220V: BK Precision 885-220V Synthesized In-Circuit LCR/ESR Meter, 0.5% Accuracy, 10kHz, 220VAC Line Input: Not Available: Discontinued: 886:

WebJul 31, 2024 · BK Precision 885 - 886 BK Precision 885 886 lcr meter aka Motech 4080 Service Manual-886 calib31072024.zip ----- 11 megs thks to all who helped me here. I … WebB&K Precision 885 Synthesized LCR/ESR Meter with SMD Probe Measurement parameters: Z, L, C, DCR, ESR, D, Q, and Ø Test conditions: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 1 Vrms, 0.25 Vrms, 0.05 Vrms 0.5% …

WebApr 12, 2007 · B&K Precision : Ean : 0817050088502 , 0094700733825 : Height: 1-57/64 inches : Item Weight: 0.640 ounces : Length: 6-57/64 inches : Measurement Type: LCR …

WebJan 26, 2024 · The 885 and 886 high accuracy LCR/ESR meters were the first handheld meters of their type on the market, offering fast, reliable, and versatile testing at a low … impact one monolight kitimpact on education due to covid 19 ukWebPrice: $505 / 3 yr Warranty Where to Buy The 878B, 879B, and 880 40,000-count handheld LCR meters measure inductance, capacitance, and resistance quickly and precisely. The 879B and 880 also measures impedance, Theta, DCR, and ESR. impact on education boulderWebOct 15, 2010 · Product Description. This handy capacitance meter (0.1 pF to 20 mF) and ohm meter (0.1 ohm to 20 megohm) also tests: transistors, beta, diodes, SCRs, LEDs … impact on education systemWebDec 10, 2024 · Bk Precision 1570a Manual BK Precision 1570a Dual Time Base Oscilloscope with probes and front face cover BK Precision 1479A Oscilloscope 30 Mhz Dynascan Tested With The B&K Precision Models 885 & 886 Synthesized In-Circuit LCR/ESR Meter is a high accuracy hand held portable test instrument used for … impact on gdp in rural india pdfWebThe B&K Precision 885 High Accuracy Handheld LCR/ESR Meter, a synthesized in-circuit meter, is the first handheld meter of this type on … impact one indian land scWebWhat's Included. The 885 and 886 high accuracy LCR/ESR meters were the first handheld meters of their type on the market, offering fast, reliable, and versatile testing at a low cost. With a wide range of test frequencies up to 10 kHz (885) and 100 kHz (886), these LCR meters can perform many different measurements: Z, L, C, DCR, ESR, D, Q, and θ. impact on family scale missing data